Details
PGI BarriAire Gold Particulate Hood Comprehensive Coverage
Extended Bib with Nomex® Nano Flex Face OpeningParticulate coverage throughout entire head including Sure‑Fit™ panel at crown. Front and back bib extends particulate barrier coverage beyond critical areas as identified by NFPA – Maximum Protection. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition. Certification to the NFPA 1971, 2018 Edition Option for Particulate Protection – Current Edition.
Fabric Description:
Quilted composite durable water resistant finish on exterior layer of jersey knit with Nomex® Nano Flex particulate barrier between the inside layer of jersey knit. Averages 95%‑98% particulate filtration efficiency that actually improves with repeated launderings.
| Fabric Performance Values | Requirements for NFPA 1971 - 2018 Edition  |  			PGI Test Results | 
|---|---|---|
| Particulate Efficiency | ≥ 90% | 96% | 
| Thermal Protective Performance (TPP) | ||
| Rib Knit | ||
 			
  |  			20.0 (min) 20.0 (min)  |  			30.2 33.1  |  		
| Quilted Composite | ||
 			
  |  			20.0 (min) 20.0 (min)  |  			29.3 30.8  |  		
| Total Heal Loss (THL) | ≥ 325 W/m2 | 401.3 W/m2 | 
| Hood Material Burst Strength | > 225 N | 614 N | 
| Flame Resistance Test Quilted Composite  |  			||
| After Flame (Wales x Courses) | ||
 			
  |  			≤ 2.0 sec ≤ 2.0 sec  |  			0.0 sec x 1.0 sec 1.0 sec x 1.0 sec  |  		
| Char Length (Wales x Courses) | ||
 			
  |  			≤ 100 mm ≤ 100 mm  |  			18 mm x 17 mm 3 mm x 2 mm  |  		
| Cleaning Shrinkage Resistance Test | ||
| Hood Measurement | ||
 			
  |  			≥ -5% | -0.3% | 
| Face Opening Measurement | ||
 			
  |  			Meets Requirement | YES | 
| Heat & Thermal Shrinkage Resistance Test | ||
| Hood Measurement | ||
 			
  |  			≥ -10% ≥ -10%  |  			0% 0%  |  		
| Face Opening Measurement | ||
 			
  |  			Meets Requirement Meets Requirement  |  			YES YES  |  		
| Seam Breaking Strength Test | ||
 			
  |  			> 181 N | 1064 N | 
| Melt or Drop When Exposed to Flame | No Melting or Dripping | NONE |